Obligatory word of warning – mucking with low-level drive settings like this can cause issues. Has anyone found a tool that can use EPC to change the Idle_b and Idle_c values for Exos drives? View an ad to download for free It’s self-hosted and self-managed, so data remains within your company network.Bank-Level EncryptionBanking-standard TLS 1.2 technology protects your computer from unauthorized access. Unparalleled PerformanceOur proprietary video-codec, DeskRT, compresses image data to reduce bandwidth and latency to a level imperceptible to the human eye. With decades of experience in IT management and later as a writer and tutor, she combines technical knowledge with a passion for clear communication.
I will optimize settings later for the security/quietness tradeoff however, I’m very pleased with it for now. How can I set this value on the Truenas interface? Keeping it spinning but not accessing data is safer. I would still recommend against idling your drive as that reduces longevity. I also set the tunable vfs.zfs.txg.timeout to a somewhat large value so the regular syncs don’t happen every 5 seconds.
Below we will discuss exactly how to do this with FreeBSD’s sesutil or the management tools for your HBA. Though a truism, it bears emphasizing that with a little planning, management and maintenance of storage systems can be made easier and safer. The total throughput possible from the connected disks is still limited by the number of lanes available, but this is likely the best approach in systems with more than a dozen disks.
Labeling with GUID Partition Table (GPT)
The APM specification dating from 1992 includes some controls for hard drives, allowing a host system to specify the desired performance level of a disk and whether standby is permitted by sending commands to a disk. In addition to the above query types, SES also supports a number of commands, including activating the “locate” and “fault” LEDs if present, and the ability to individually power off drives. The first step is to map out the relationship between the physical chassis where the disks reside, and the logical devices enumerated by the operating system.
- For ZFS users, automating fault responses with tools like ZED (ZFS Event Daemon) can simplify disk replacement and minimize downtime.
- While both SATA and SAS allow multiple commands to be issued at once to the device, these commands cannot actually be executed concurrently—instead, they are queued for sequential operation.
- 1 SSD to boot and 1 HDD to store data.
- It is very popular among professionals who provide technical support.
- If we wanted to allow the disk to still park its heads but at minimum frequency, setting the APM value to 7Fh (hdparm -B 127) seems to be the correct choice.
- The map command displays all of the SES devices and each element (this is the nomenclature in SES) connected to them.
This will activate the fault LED for element 9 (Slot 08) on the first SES device. You can avoid any uncertainty by enabling the “locate” or “fault” LED for the drive you mean to replace. This example creates a new GPT partition scheme on da36, creates a 4 GiB swap partition aligned to 1 MiB boundaries, and then adds a ZFS partition with the label e3s01-ZGY0XH87 using the remainder of the space on the disk.
An essential remote access program
- Ensure device health & easy replacements with these valuable tips.
- To prevent parking the heads at all a value greater than 128 may do the job (254 is a common choice, as the highest-power setting available), but it’s possible that some disks won’t behave this way because the ATA specification refers only to spinning down the disk and does not specify anything about parking heads.
- We are going to focus on some of the most popular for SATA and SAS drives.
- Hello,Like many users of Seagate Exos drives, I have found that they park their heads very aggressively, approximately every 2 minutes.
- Secondly what are your disk monitoring refresh intervals and what do you use on your system to monitor SMART disk health?
- My question is – is there a way to tell if a certain disk suffers from the issue prior to purchasing?
For chassis with larger numbers of drives, or when connecting external JBOD chassis, it is common for the drives to connect to a specialized board that provides power and routing for the SATA/SAS signals to the controller. When building a storage system, there are many different ways the disks might be connected to the system. NVME-oF allows storage devices and arrays in remote chassis to be connected to local motherboards. NVMe storage comes in many form factors, from small M.2 devices to U.2 and other hot-swappable formats intended for servers. NVMe connects storage devices directly to the PCIe bus, offering extremely low latency and high throughput.
If your system has multipath SAS, each disk will be present more than once, and you should use the gmultipathcommand to deduplicate your disks and for labeling as well. FreeBSD supports a number of different ways to label the disk, depending on your use case. The map command displays all of the SES devices and each element (this is the nomenclature in SES) connected to them. Of course, all of this chassis management technology isn’t very effective without tools to make it usable. It also provides information about each slot in the enclosure (even if empty), including a flag to indicate if the device has recently been swapped.
Storage Media Options
I noticed that even when doing nothing, I hear the sound of drives working every few seconds. I gave up and just built a Windows Storage Space with tiering and the drives are now effectively silent. I guess it depends on the drives, but don’t think you’ll find any software solution. My Seagate Exos enterprise drives make almost 0 noise actually. The system is never idle really, it’s a server. What causes the constant load on the disk?
Using the no-op true command on other paths to that disk, will cause GEOM to re-”taste” the disk and see the label and automatically add the additional paths to the existing multipath. This will write a GEOM Multipath label to the last sector of the disk. Each SAS Expander will present as a new /dev/ses# device, so your system may have more than one.
sesutil map
SAS disk reservations provide the ability to connect to the disk redundantly—or even across multiple machines—while ensuring it is only used by one of them at a time. SAS provides many more features than SATA does—including full duplex operations, advanced error recovery, multipath, and disk reservations. It too was an extension on an existing interface bus which offered greatly improved performance. SATA+AHCI improved data transfer speeds, simplicity of communication, and included abilities that we today take for granted, such as “hot swap” and command queueing. These concepts also apply to other operating systems, but the tools might differ slightly.
AnyDesk for Windows
It is fairly well-known among techies that hard drives used in server-like workloads can suffer from poor configuration by default such that they frequently load and unload their heads, which can cause disks to fail much faster than they otherwise would. My Seagate Archive SMR disk (which began life as an external hard drive and was retired from that role when it became too small to hold as much as I wanted to back up to it) apparently doesn’t support reporting EPC settings (since asking for them says so), and initially didn’t accept new values for the idle timers either. The Prometheus Node Exporter is the canonical tool for capturing machine metrics like utilization and hardware information with Prometheus, but it alone does not support probing SMART data from storage drives. While SSDs don’t have any heads to park, most do report a media_wearout_indicator that represents the amount of data written to the device in relation to the amount that it’s specified to accept before the Flash storage medium wears out.
While I have been aware of this in my home server as well, it is easy to forget to ensure that disks are not silently killing themselves by cycling the heads. With modern, especially Enterprise grade hard drives being able to have hundreds of thousands of head park operations in their service life, is this really an isssue? With the tools presented here, the reader is well armed to react to failed disks and ensure that the wrong disk isn’t accidentally pulled. However, if a disk has died entirely, or a slot is empty, it might not have a device name. Sesutil can also be used to locate the disk in the physical array.While the SES data tells us that there is an 8 TB disk in Slot 06, it does not tell us which slot in the chassis corresponds to 06. Looking at a few items from the output, we can see the device names (/dev/da0 and /dev/da7 respectively) of the disks in Slot00 and Slot07.
It’s hard to imagine why your drives are that loud! It’s a datacenter drive, very loud, so it’s still audible. For quietness, a noise reveryplay reducing case, move it somewhere else, quieter drives, maybe SSD instead of hard drives, etc.